Prior to testing, EN 196 requires prisms to be cured for a period of at least 24 hours at 20 ±1ºC, 90 % RH minimum. The prisms are then de-moulded and stored under water for the required curing time, usually 48 hours, 72 hours, 7 and 28 days.
Digital data logger for use with 39-1300 Humidity Cabinet.
info »Prior to testing, EN 196 requires prisms to be cured for a period of at least 24 hours at 20 ±1ºC, 90 % RH minimum. The prisms are then de-moulded and stored under water for the required curing time, usually 48 hours, 72 hours, 7 and 28 days.
The Humidity Cabinet is built to a high specification and is designed for the early curing of mortar prisms prior to storing under water. Relative humidity up to 98%.
Please note 39-1300/24 Digital Recorder is optional, but must be ordered with the cabinet so they may be calibrated together.
info »Prior to testing, EN 196 requires prisms to be cured for a period of at least 24 hours at 20 ±1ºC, 90 % RH minimum. The prisms are then de-moulded and stored under water for the required curing time, usually 48 hours, 72 hours, 7 and 28 days.
The Humidity Cabinet is built to a high specification and is designed for the early curing of mortar prisms prior to storing under water. Relative humidity up to 98%.
Please note 39-1300/24 Digital Recorder is optional, but must be ordered with the cabinet so they may be calibrated together.
info »This cabinet has a stainless steel interior and it is fitted with adjustable shelves. It also has sealed chambers making it suitable for humidity’s up to 98%. This can have an outer door heater to demist the inner toughened glass viewing door. Two 12 mm access ports are provided as standard.
Monitoring and control of both heating and cooling functions are performed with great accuracy, and achieves typical temperature stability of ±0.5°C. The LED digital display allows the temperature performance to be easily verified. A digitally set over temperature safety cut-out is fitted to all models.
For 220 – 240 V AC, 50 Hz, 1 ph.
info »This cabinet has a stainless steel interior and it is fitted with adjustable shelves. It also has sealed chambers making it suitable for humidity’s up to 98%. This can have an outer door heater to demist the inner toughened glass viewing door. Two 12 mm access ports are provided as standard.
Monitoring and control of both heating and cooling functions are performed with great accuracy, and achieves typical temperature stability of ±0.5°C. The LED digital display allows the temperature performance to be easily verified. A digitally set over temperature safety cut-out is fitted to all models.
For 220 – 240 V AC, 60 Hz, 1 ph.
info »