• Optional calibration to BS EN ISO376 Grade 1
• Various capacities up to 3000 kN
• 7½ digit high-resolution hand-held readout
• Designed for the calibration and verification of concrete compression machines
The ELE electronic 2000 kN load cell and readout unit is an accurate and sensitive system for the calibration and verification of the load measuring systems of concrete compression machines. Each system is supplied complete with NPL (National Physical Laboratory UK) calibration certificate in compliance with BS EN ISO376 Grade 1.
Complete with Hand Held Readout Unit & UKAS certificate.
The 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions.
Applications: Reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.
info »Complete with Hand Held Readout Unit & traceable certificate (not calibrated to UKAS standards). Upon receipt, customer may calibrate to NIST or other standard.
The 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions.
Applications: Reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.
info »Complete with Hand Held Readout Unit and UKAS calibration certificate.
The 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions.
Applications: Reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.
info »Upon receipt, customer may calibrate to NIST or other standard.
The 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions.
Applications: Reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.
info »Complete with Hand Held Readout Unit and UKAS calibration certificate.
This Load Cell is supplied with rechargeable batteries and universal charger.
info »Complete with Hand Held Readout Unit and traceable certificate (not calibrated to UKAS standards). Upon receipt, customer may calibrate to NIST or other standard.
info »The 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions.
Applications: Reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.
info »The CCDHA 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions.
These high accuracy load cells have the option of submersible versions and models with on-board signal conditioning. The CCDHA high accuracy load cells can be supplied with a BS EN ISO 376 calibration certificate issued by a UKAS laboratory if required.
Application: reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.
•Fully Submersible IP67 or IP68 Rated
•Other Ranges Available on Request
•Equivalents to Other Manufacturers
•Full Range of Mounting Options Inc.: Custom/Standard Loading Caps, Custom Mounting Bases
•Calibration to BS EN ISO376
•Versions Available with Integral Signal Amplifiers
•Shunt Calibration
•Different Cable Lengths
•Internal Signal Amplifiers
•TEDS (Transducer Electronic Data Sheet)
•TEDS Allows Plug & Play with TEDS Enabled Instrumentation.
•USB Version (via DSC-USB)
•Vacuum Application Version
•Single or Multi-Channel PC-Based Monitoring & Data Logging System
•Wireless Version (via T24 instrumentation)
info »
The 37-8315/10 handheld display is a completely portable high precision instrument designed to work with all types load cells and strain gauge based transducers. The 7-digit LCD display makes it suitable for any monitoring application from general industrial up to high accuracy reference standards.
The 37-8315/10 comes packaged in a compact and enclosure which weighs only 260 grams and is powered by 2x ‘AA’ batteries that provide up to 450 hours of continuous operation in low power mode with a 350Ω load cell or strain gauge bridge connected.
For simplified use, the operator only has access to six keys; on/off, gross/net, peak, trough, hold and shunt cal. Calibration and configuration can be performed from the front panel, with protection against accidental or un-intentional changes. The configuration menu is very simple and enables the setting of a tare value, display resolution, filter rate, auto power off and selection of low power mode.
There are 3 calibration options; a single pass auto-calibration, entering of load cell sensitivity and corresponding display value and entering of offset and gain values for corresponding display values. The display also offers TEDS (Transducer Electronic Data Sheet) functionality allowing automatic calibration with any compatible sensor to which it is connected.
The 37-8315/10 has a dual range facility allowing for calibration in two different engineering units, i.e. lbs/kg, tonne/kN which offers the engineer the ability to tailor the instruments response to the application.
info »