• Ideally suited for use on bridge decks, concrete piers and docks, highway slabs and parking garages.
• Complete system packaged in a convenient carrying case for easy transport to the field.

Half cell potential measurements serve as an important means of determining the probability of corrosion activity on the structure reinforcing steel. These measurements, which are related to the electrochemical nature of corrosion, allow an accurate survey to be performed in a short period of time.

Data from these surveys can be plotted to provide an easy to interpret graphic picture of the structure. From these plots, probable corrosion areas and the total area of the structure subject to corrosion can be determined.

The Corrosion Mapping System consists of all the necessary items required to perform this test in accordance with ASTM C-876 Testing Standard.

Corrosion Mapping System

The 35-2165 Corrosion Mapping System consists of a voltmeter, a portable surfactant reservoir with electrode, 250 ft. (76 m) test wire with a hand reel, an adaptor plate, two 15" (381 mm) long electrode extensions, copper sulphate crystals, anti-freeze and concentrated surfactant solutions. Ideally suited for use on bridge decks, concrete piers and docks, highway slabs and parking garages, the Corrosion Mapping System is packaged in a convenient carrying case for easy transport.

info »
35-2165