Tri-Flex 2 One-Cell Triaxial Test Set 220 vAC English

« return

Tri-Flex 2 One-Cell Triaxial Test Set 220 vAC English

2000/01

Category:

Soils

Sub Category:

Soil Strength (Triaxial), Triaxial Test Sets

Product Group:

Tri-Flex 2 One-Cell Triaxial Test Set

Set Includes:

1 - Tri-Flex 2 Master Control Panel (25-0696/0x or 25-0697/0x).
1 - Tri-Flex 2 Water De-airing Tank System (25-0698).
1 - Digital Tritest 50 Load Frame (25-3518/0x).
1 - Proving Ring, 1,000 lb. (4.5 kN) (78-0260).
1 - Strain Dial Indicator (88-4100 or 25-4210).
1 - Digital Pressure Gauge (27-1620).
1 - Triaxial Cell (25-4117).
3 - No-Volume Change Valves (25-4520).
1 - 2.8” or 70 mm Base Pedestal (25-4178 or 25-4176).
1 - 2.8” or 70 mm Specimen Cap (25-6630 or 25-6430).
2 - 2.8” or 70 mm Drainage Lines (25-6430/10).
1 - 2.8” or 70 mm Porous Stones. Pack of 2 (25-6721 or 25-6561).
1 - 2.8” (70 mm) Sealing Rings. Pack of 10 (25-6641).
1 - 2.8” (70 mm) Filter Paper Drains. Pack of 50 (25-6580).
1 - 2.8” (70 mm) Filter Paper Discs. Pack of 100 (25-6585).
2 - 2.8” (70 mm) Rubber Membranes. Pack of 10 (25-6441).
1 - 2.8” (70 mm) O-ring Placing Tool (25-6470).
1 - 2.8” (70 mm) Membrane Tester (25-6443).
1 - 2.8” (70 mm) Two-Part Split Mold (25-6690).
1 - 2.8” (70 mm) Suction Membrane Device (25-6480).
1 - 2.8” (70 mm) Two-Way Split Former (25-6680 or 25- 6500).

220vAC, 50/60 Hz, 1ø.

Rated Power 220vAC, 50/60Hz, 1ø.
ASTM D2850 Yes
ASTM D4767 Yes
AASHTO T296 Yes
AASHTO T297 Yes
Description Tri-Flex 2 One-Cell Triaxial Test Set 220 vAC English

Tri-Flex 2 One-Cell Triaxial Test Set 110 vAC English

2000/02

Set Includes: 1 - Tri-Flex 2 Master Control Panel (25-0696/0x or 25-0697/0x).1 - Tri-Flex 2 Water De-airing Tank System (25-0698).1 - Digital Tritest 50 Load Frame (25-3518/0x).1 - Proving Ring, 1,000 lb. (4.5 kN) (78-0260).1 - Strain Dial Indicator (88-4100 or 25-4210).1 - Digital Pressure Gauge (27-1620).1 - Triaxial Cell (25-4117).3 - No-Volume Change Valves (25-4520).1 - 2.8" or 70 mm Base Pedestal (25-4178 or 25-4176).1 - 2.8" or 70 mm Specimen Cap (25-6630 or 25-6430).2 - 2.8" or 70 mm Drainage Lines (25-6430/10).1 - 2.8" or 70 mm Porous Stones. Pack of 2 (25-6721 or 25-6561).1 - 2.8" (70 mm) Sealing Rings. Pack of 10 (25-6641).1 - 2.8" (70 mm) Filter Paper Drains. Pack of 50 (25-6580).1 - 2.8" (70 mm) Filter Paper Discs. Pack of 100 (25-6585).2 - 2.8" (70 mm) Rubber Membranes. Pack of 10 (25-6441).1 - 2.8" (70 mm) O-ring Placing Tool (25-6470).1 - 2.8" (70 mm) Membrane Tester (25-6443).1 - 2.8" (70 mm) Two-Part Split Mold (25-6690).1 - 2.8" (70 mm) Suction Membrane Device (25-6480).1 - 2.8" (70 mm) Two-Way Split Former (25-6680 or 25- 6500).

Tri-Flex 2 One-Cell Triaxial Test Set 110 vAC Metric

2001/02

Set Includes: 1 - Tri-Flex 2 Master Control Panel (25-0696/0x or 25-0697/0x).1 - Tri-Flex 2 Water De-airing Tank System (25-0698).1 - Digital Tritest 50 Load Frame (25-3518/0x).1 - Proving Ring, 1,000 lb. (4.5 kN) (78-0260).1 - Strain Dial Indicator (88-4100 or 25-4210).1 - Digital Pressure Gauge (27-1620).1 - Triaxial Cell (25-4117).3 - No-Volume Change Valves (25-4520).1 - 2.8” or 70 mm Base Pedestal (25-4178 or 25-4176).1 - 2.8” or 70 mm Specimen Cap (25-6630 or 25-6430).2 - 2.8” or 70 mm Drainage Lines (25-6430/10).1 - 2.8” or 70 mm Porous Stones. Pack of 2 (25-6721 or 25-6561).1 - 2.8” (70 mm) Sealing Rings. Pack of 10 (25-6641).1 - 2.8” (70 mm) Filter Paper Drains. Pack of 50 (25-6580).1 - 2.8” (70 mm) Filter Paper Discs. Pack of 100 (25-6585).2 - 2.8” (70 mm) Rubber Membranes. Pack of 10 (25-6441).1 - 2.8” (70 mm) O-ring Placing Tool (25-6470).1 - 2.8” (70 mm) Membrane Tester (25-6443).1 - 2.8” (70 mm) Two-Part Split Mold (25-6690).1 - 2.8” (70 mm) Suction Membrane Device (25-6480).1 - 2.8” (70 mm) Two-Way Split Former (25-6680 or 25- 6500).

Tri-Flex 2 One-Cell Triaxial Test Set 220 vAC Metric

2001/01

Set Includes: 1 - Tri-Flex 2 Master Control Panel (25-0696/0x or 25-0697/0x).1 - Tri-Flex 2 Water De-airing Tank System (25-0698).1 - Digital Tritest 50 Load Frame (25-3518/0x).1 - Proving Ring, 1,000 lb. (4.5 kN) (78-0260).1 - Strain Dial Indicator (88-4100 or 25-4210).1 - Digital Pressure Gauge (27-1620).1 - Triaxial Cell (25-4117).3 - No-Volume Change Valves (25-4520).1 - 2.8” or 70 mm Base Pedestal (25-4178 or 25-4176).1 - 2.8” or 70 mm Specimen Cap (25-6630 or 25-6430).2 - 2.8” or 70 mm Drainage Lines (25-6430/10).1 - 2.8” or 70 mm Porous Stones. Pack of 2 (25-6721 or 25-6561).1 - 2.8” (70 mm) Sealing Rings. Pack of 10 (25-6641).1 - 2.8” (70 mm) Filter Paper Drains. Pack of 50 (25-6580).1 - 2.8” (70 mm) Filter Paper Discs. Pack of 100 (25-6585).2 - 2.8” (70 mm) Rubber Membranes. Pack of 10 (25-6441).1 - 2.8” (70 mm) O-ring Placing Tool (25-6470).1 - 2.8” (70 mm) Membrane Tester (25-6443).1 - 2.8” (70 mm) Two-Part Split Mold (25-6690).1 - 2.8” (70 mm) Suction Membrane Device (25-6480).1 - 2.8” (70 mm) Two-Way Split Former (25-6680 or 25- 6500).
We use cookies to provide website functionality and to analyse traffic on our website. We (and our service providers) use small text files called cookies and similar technology on your device. These cookies do not reveal your identity, web use or other behaviour. Our Cookie Statement provides more information and explains how to update your cookie settings. View our cookies policy.