< Previous170Chemical TestsCementtel: +44 (0)1525 249 200 • email: ele@eleint.co.uk • www.ele.comFlame Photometer AccessoriesRegulators for Natural GasProduct Code: 38-0270Product Standards:EN 196-2 (EN 196-21), ASTM C114Regulators for Propane GasProduct Code: 38-0280Product Standards:EN 196-2 (EN 196-21), ASTM C114Air CompressorProduct Code: 38-0320/01Product Standards:EN 196-2 (EN 196-21), ASTM C114Supplies air at 6 litres/minute at a pressure of 1 kg/cm2, for use with 38-0200/01 Flame Photometer.SpecificationsPower Supply220-240 V AC, 50-60 Hz, 1 phCalcium FilterProduct Code: 38-0250Product Standards:EN 196-2 (EN 196-21), ASTM C114Barium FilterProduct Code: 38-0260Product Standards:EN 196-2 (EN 196-21), ASTM C114171FinenessCementwww.ele.com • email: ele@eleint.co.uk • tel: +44 (0)1525 249 200Determination of Fineness Blaine ApparatusThe fineness of cement is a property that must be carefully controlled during the manufacturing process. The total specific surface of the cement represents the surface area available for hydration. Various methods are in use to measure the specific surface of cements. For most purposes air permeability methods produce accurate, repeatable results.This method has been adopted in Europe as the definitive means of determining the fineness of cement and other powder materials. The system is supplied complete with Stainless Steel cell, perforated disc and plunger, manometer U-tube, aspirator, bottle of manometer liquid and a box of filter papers.Blaine Air Permeability ApparatusProduct Code: 38-1000Product Standards:EN 196-6, ASTM C204, AASHTO T153SpecificationsCellStainless Steel; 12.70 ± 0.10 mm i.d.Disk0.9 ± 0.1 mm thick with 30-40 one mm dia holesPlungerStainless SteelManometerU-tube glass with ground joint, stop cock and rubber bulb assemblyFilter Paper12.70 mm diaFluidPure Mineral OilWeightNet 7 lbs. (3.2 kg)Spares/Consumables:Manometer U-tube (38-1000/10)Aspirator (38-0500/11)Blaine Air Permeability Cell (38-1000/15)Perforated Disc (38-1000/17)Filter Papers (38-0650)Reference Cement 5 g Sachet (38-0645)Reference Cement (5 g Sachet)Product Code: 38-0645Product Standards:EN 196-6, ASTM C204, AASHTO T153)Filter PapersProduct Code: 38-0650Product Standards: EN 196-6, AASHTO T15312.7 mm diameter. Box of 100.Product Standards:EN 196-6, ASTM C204, AASHTO T153Stainless Steel with a perforated disc and plunger.Spares/Consumables:Perforated Disc (38-1000/17)Manometer U-tubeProduct Code: 38-1000/10Product Standards:EN 196-6, ASTM C204, AASHTO T153Pure Mineral Oil 1 Litre BottleProduct Code: 38-0620Product Standards:EN 196-6, ASTM C204, AASHTO T153Blaine Air Permeability CellProduct Code: 38-1000/15tel: +44 (0)1525 249 200 • email: ele@eleint.co.uk • www.ele.com172FinenessCementSpecific Gravity (Relative Density) of Hydration CementIt is necessary to know the specific gravity of cement for various reasons related to its quality and use. In particular it will be necessary to determine the specific gravity as part of the determination of the specific surface of a cement. The ELE Le Chatelier Flask is a high specification unit that is individually calibrated and supplied with calibration certificate.Le Chatelier FlaskProduct Code: 38-1200Product Standards:EN 196-6, ASTM C128, ASTM C188, E 694, AASHTO T133For determining the density of hydraulic cement and lime, supplied complete with calibration certificate. Capacity 250 ml. Graduated from 0 to 1 ml and from 18 to 24 ml graduations. Accurate to 0.05 ml.SpecificationsGraduationsZero mark represents 250 ml, the capacity of the large bulb; neck graduations from 0-1 ml in 0.1 ml divisions with two extra 0.1 ml graduations above the 1.0 and below the 0 marks; bulb portion of neck holds 17 ml; top portion of neck graduated from 18-24 ml in 0.1 ml divisions; 24 ml capacityStopperGround glassWeightNet 8 oz. (227 g)Consistency, Setting Time, Workability & FlowDetermination of setting time and soundness of cement requires the use of a neat cement paste of standard consistence. The Vicat method is usually specified as the test used to determine the water content which will produce the desired consistence.Concrete Mortar PenetrometerThe Concrete Mortar Penetrometer is used for field and laboratory evaluations of the initial set of concrete mortars. The test involves inserting the penetrometer shaft to a depth of 25.4 mm at constant rate and time interval. The resistance in lbf/in² is shown on the penetrometer’s direct-reading scale.Product Standards:ASTM C403/C403M, AASHTO T197Supplied complete with belt-loop, canvas carrying case.SpecificationsNeedleSteel shaft; 1/20 sq. in. surface areaRange0 to 700 psiScaleDirect-reading; indicator sleeve holds reading until releasedDimensionsDia. x Length3/4 inches (19 mm) x 7 inches (178 mm)Carrying CaseCanvas, with belt-loopWeightNet 8 oz. (227 g)Spares/Consumables:Spare Indicator Ring (194150033)Pocket Concrete PenetrometerProduct Codes: 38-2696www.ele.com • email: ele@eleint.co.uk • tel: +44 (0)1525 249 200173Consistency, Setting Time, Workability & FlowCementFlow Table Product Code: 38-6000Product Standards:ASTM C230/C230MManufactured from cast bronze as specified in BS and ASTM C230. Complete with Tripod and Baseplate.SpecificationsDimensions W x D x H (m)0.6 x 0.42 x 0.43Weight (kg)25Spares/Consumables:BS/ASTM Flow Table Top (38-6000/10)Tripod (38-6020)Baseplate (38-6060)Flow MouldProduct Code: 38-6040Product Standards:ASTM C230/C230MManufactured from bronze as specified in BS and ASTM.Calipers ASTMProduct Code: 38-6080Product Standards: ASTM C230/C230MFor measuring the diameter of the sample.SpecificationsDimensions W x D x H (m)0.04 x 0.1 x 0.33Weight (kg)0.2Plastic TamperProduct Code: 38-6160Product Standards: ASTM C230/C230MSpecificationsDimensions W x D x H (m)0.142 x 0.025 x 0.155Motorised Unit for 38-6000 Flow TableProduct Code: 38-6100/01, 38-6100/06Product Standards:ASTM C230/C230MFor use with 38-6000 Flow Table. Operates the cam at a speed of 100 rpm. For 220-240 V AC, 50 Hz, 1 ph.SpecificationsDimensions W x D x H (m)0.39 x 0.55 0.22Weight (kg)5Product Code:Power Supply38-6100/01220-240 V AC, 50 Hz, 1 ph38-6100/06220-240 V AC, 60 Hz, 1 phFlow & Workability of Mortar LimeTo perform this test, a sample is placed on a metal surface which is then raised and dropped through a known height.tel: +44 (0)1525 249 200 • email: ele@eleint.co.uk • www.ele.com174Consistency, Setting Time, Workability & FlowCementVicat MethodThis procedure is used to determine the quantity of water required to produce a cement paste of standard consistence.Vicat FrameProduct Code: 38-4010Initial & Final Set Needle ENProduct Code: 38-4010/13Product Standards:EN 196-3, EN 480-2, EN 13454-21.13 mm diameter.Initial Set Needle ASTMProduct Code: 38-4010/10Product Standards:ASTM C187, ASTM C191, AASHTO T129, AASHTO T1311 mm diameter.Product Standards:EN 196-3, EN 480-2, EN 13454-2, ASTM C187, ASTM C191, AASHTO T129, AASHTO T131Complete with consistency plunger, 10 mm diameter. Requires one initial or final set needle to make up test weight to 300 g (less Needle Sets and Moulds).SpecificationsWeight (kg)1.3Spares/Consumables:Consistency Plunger (38-4010/14)Accessories:ASTM Vicat Mould (38-2660)EN Vicat Mould (38-2300)Vicat Mould (38-2200)Engineer’s Steel Rule (81-0805)Harvard Trip Balance (78-7090)Weights for Harvard Trip Balance (78-7110)ASTM Initial Set Needle (38-4010/10)EN Initial Needle (38-4010/11)EN Final Needle (38-4010/12)EN Set of Needles (38-4010/13)www.ele.com • email: ele@eleint.co.uk • tel: +44 (0)1525 249 200175Consistency, Setting Time, Workability & FlowCementAutomatic VicatThe Automatic Vicat Apparatus executes the test program using a fully automatic test cycle. The integral LCD display indicates test progress in real time. Firmware in the unit enables up to five user test profiles to be established. Integrated on-board memory will store up to 50 complete tests. On completion of the test the integral printer automatically prints all test data including a graph penetration with related data. As standard, the unit includes an RS232 serial port for connection to PC which, when used in conjunction with the supplied software, enables users to manage test data including graphing and report generation. The timed cycle of events is operator-selectable and penetrations can be selectable at intervals of 30 seconds, 1, 5, 15 or 30 minutes.Automatic Vicat ApparatusProduct Code: 38-2015/01Product Standards:EN 196-3, EN 480-2, EN 13454-2, ASTM C187, ASTM C191, AASHTO T129, AASHTO T131Complete with EN and ASTM Initial and Final needles, Consistency Plunger, Windows® software and RS232 cable, 1 x EN and ASTM Mould and Glass Plate. Suitable for continuous use in saturated humidity, at a controlled temperature of 20°C ± 1°C.SpecificationsPower Supply220-240 V AC, 50-60 Hz, 1 phSpares/Consumables:ASTM Initial and Final Set Needle (38-2023)Consistency Plunger (38-2015/16)EN Initial and Final Set Needle (38-2021)Accessories:ASTM Vicat Mould (38-2660)EN Vicat Mould (38-2300)Vicat Mould (38-2200)Needle Cleaning Device (38-2015/12)Printer Paper Rolls (38-2015/14)Mould Tank (38-2015/15)Weight, 700 g (38-2015/17)Accessories Kittel: +44 (0)1525 249 200 • email: ele@eleint.co.uk • www.ele.com176Consistency, Setting Time, Workability & FlowCementMould TankProduct Code: 38-2015/15Product Standards:EN 196-3For testing samples under water as per EN 196-3, for use in temperature controlled laboratories.Printer Paper Rolls (Pack of 10) For Automatic VicatProduct Code: 38-2015/14Consistency PlungerProduct Code: 38-2015/16Product Standards:EN 196-3, EN 480-2, EN 13454-2, ASTM C187, ASTM C191, AASHTO T129, AASHTO T131Initial & Final Set Needle ENProduct Code: 38-2021Product Standards:EN 196-3, EN 13454-2, EN 480-23 mm + 1.13 mm diameter with special footing.Initial & Final Set Needle ASTMProduct Code: 38-2023Product Standards:ASTM C187, ASTM C191, AASHTO T129, AASHTO T1311 mm + 1 mm diameter with special footing.Automatic Vicat Needle Cleaning DeviceProduct Code: 38-2015/12www.ele.com • email: ele@eleint.co.uk • tel: +44 (0)1525 249 200177Consistency, Setting Time, Workability & FlowCementVicat MouldProduct Code: 38-2200Product Standards:BS 4550-3-3.5, BS 4550-3-3.6Manufactured from brass and supplied complete with a ring and glass base plate.Vicat Mould ENProduct Code: 38-2300Product Standards:EN 196-3, EN 13454-2, EN 480-2Manufactured from a hard rubber compound and supplied complete with a glass base plate.Vicat Mould ASTMProduct Code: 38-2660Product Standards:ASTM C187, ASTM C191, AASHTO T129, AASHTO T131Manufactured from non-absorbent plastic and supplied complete with a glass base plate.tel: +44 (0)1525 249 200 • email: ele@eleint.co.uk • www.ele.comSpecificationsWeight (kg)0.4Tamping Rod for Le Chatelier MouldProduct Code: 38-3300178SoundnessCementSoundnessThe soundness of cement and hydrated lime is of particular importance. It is essential that once hardened the paste does not undergo a large change in volume. The soundness of cements and limes can be determined by an expansion test using Le Chatelier Moulds. The method of curing lime differs from that of cements, lime being cured in a steam tank and cements in a water bath. The ASTM method uses a high-pressure steam vessel (Autoclave) to cure the specimens.General Expansion of Dry Hydrated Lime by the Le Chatelier MethodLe Chatelier MouldProduct Code: 38-3005Product Standards:BS 6463-4, EN 196-3, EN 459-2Comprising a split cylinder fitted with two indicator stems. The mould is supplied complete with two glass plates and a weight 100 g ± 10 g. Three moulds required for each test.SpecificationsWeight (kg)0.9Extensibility of Mould Apparatus BS Product Code: 38-3200Extensibility of Mould Apparatus ENProduct Code: 38-3205Product Standards:EN 196-3, EN 459-2The unit comprises a metal sleeve with a hook and set screw to fit over one of the mould pointers, and a clamp to fit onto the other pointer of the mould. Supplied complete with one weight 300 g ±1 g.Product Standards:BS 6463-4The unit comprises a metal sleeve with a hook and set screw to fit over one of the mould pointers, and a clamp to fit onto the other pointer of the mould. Supplied complete with one weight 100 g ±1 g.SpecificationsWeight (kg)0.1Product Standards:BS 6463-417 mm end diameter.SpecificationsWeight (kg)0.07Soundness of Cement Paste Test SetGrouped Product Standards:EN 196-3Set Contains:Product CodeProductQty38-3005Le Chatelier Mould338-3205Extensibility of Mould Apparatus EN138-3420/01Le Chatelier Water Bath1Additional Set Items81-0335Trowel BS 4550124-0430Glass Plate1www.ele.com • email: ele@eleint.co.uk • tel: +44 (0)1525 249 200179SoundnessCementSoundness of Cement Paste by the Le Chatelier MethodLe Chatelier Water Bath Product Code: 38-3420/01Product Standards:BS 6463-4, EN 196-3, EN 459-2Manufactured from corrosion resistant material, complete with a removable rack to hold up to 12 moulds and timer unit.SpecificationsWeight (kg)5.4Spares/Consumables:Element (38-3420/10)Switch (SP16522)Heating Element Seal (38-3420/11)Heating TimerSoundness of Portland Cement by the Autoclave MethodSpecimens are cured in a high-pressure steam vessel and the change in specimen length is determined using Drying, Shrinkage and Moisture Movement Apparatus. Note: This unit draws a current of 20 amps.AutoclaveProduct Code: 38-3800/01Product Standards:ASTM C151, AASHTO T107The Autoclave provides high pressure steam curing of the specimens and is supplied with a safety valve, pressure gauge and controlled heater unit. The pressure vessel is independently certified and certificated. A specimen rack with capacity for 12 specimens included. The unit conforms to the requirements of ASTM C151. 220-240 V AC, 50-60 Hz, 1 ph.SpecificationsPower Supply220-240 V AC, 50-60 Hz, 1 phSpares/Consumables:Safety relief valve (5021A0038)Vent valve (1135A0050)Gauge (5022A0118)Heating element (38-3800/14)Specimen Rack (38-3800/15)Vent valve Seal (8439X0203))Autoclave Lid Sealing GasketProduct Code: 38-3800/13Autoclave Spares KitProduct Code: 38-3800/K1Spares Kit Includes: QtyHeating Element 110/240 V Dual Voltage 1Lid Gasket5Energy Regulator 240 V1 Safety Relief Valve. 707-11 MD Safety VV set at 350 psi 15 mm: complete with certificates1Folded Copper Washer; 1/2 BSP5Folded Copper Washer; 3/8 BSP1Valve Assembly for Autoclave1Next >