25-0690
Category:
Soils
Sub Category:
Permeability
Product Group:
Tri-Flex 2 Permeability Test Cell, Tri-Flex 2 One-Cell Permeability Test System
Maximum Pressure, psi | 150 |
ASTM D5084 | Yes |
Description | Tri-Flex 2 Permeability Test Cell |
Specimen Size | 1.4” (35 mm) to 4” (102 mm) diam. Using optional Cap and Base Sets, not included. |
Head Assembly | Anodized aluminum with quick-disconnect fill/vent port and three clamping rods. |
Base Assembly | Stainless steel with four stainless steel no-volume change ball valves for inflow and outflow ports and one brass no-volume change ball valve for lateral port. |
Cylinder | Clear acrylic. |
Maximum Pressure | 15 0 psi (1,034 kPa). |
Tubing | Teflon and stainless steel. |
Dimensions | Approx. 8” diam. x 15 ” h. (203 x 381 mm). Excluding valves. |
Weight | Net 23 lbs. (10.4 kg). |
Specimen Size | 1.4” (35 mm) to 4” (102 mm) diam. Using optional Cap and Base Sets, not included. |
Head Assembly | Anodized aluminum with quick-disconnect fill/vent port and three clamping rods. |
Base Assembly | Stainless steel with four stainless steel no-volume change ball valves for inflow and outflow ports and one brass no-volume change ball valve for lateral port. |
Cylinder | Clear acrylic. |
Maximum Pressure | 15 0 psi (1,034 kPa). |
Tubing | Teflon and stainless steel. |
Dimensions | Approx. 8” diam. x 15 ” h. (203 x 381 mm). Excluding valves. |
Weight | Net 23 lbs. (10.4 kg). |
25-0695
n with Viton diaphragm and O-rings. Supplied with all necessary valves and tubing. The Pressure Interface Chamber (PIC) is used during permeability test application involving toxic permeants. The chambers provide a closed system for toxic liquids entering and exiting the test cell. Weight: 5.5 kg (net 12 lbs)25-7621
). 300 mm length x 0.5 mm thickness. Black sealing rings pictured are sold seperately (25-7631 100 mm).